DNA Computing Based Genetic Algorithm by Jili Tao & Ridong Zhang & Yong Zhu
Author:Jili Tao & Ridong Zhang & Yong Zhu
Language: eng
Format: epub
ISBN: 9789811554032
Publisher: Springer Singapore
6.2 The Coke Unit
The whole process flow is shown in Fig. 6.1. It consists of such equipment as one fractionating tower (T102), three coke furnaces (F101/1, 2, 3), and six coke towers (T101/1, 2, 3, 4, 5, 6). The detailed flow of each part of the unit is shown in Fig. 6.2, its main job is to coke residual oil. Take furnace (F101/3) as an example, the process flow is as follows: The flow of residual oil is divided into two branches (FRC8103, FRC8105) and sent into the convection chamber of the furnace (F101/3) to be heated to about 330 °C, then the two branches are combined and flow out of the radiation chamber of the furnace and go to the fractionating tower (T102) for heat exchange with gas oil from the coke towers (T101/5, 6). After heat exchange, the heavy part of both residual oil and the gas oil join together, which is called circulating oil. The circulating oil is then divided into two branches (FRC8107, FRC8108) by pumps (102/1, 2, 3) and returned to enter the radiation chamber of the furnace (F101/3) to be heated to about 495 °C. Finally, the two branches join together and go to the coke towers (T101/5, 6) to remove coke. This process is called the coking of residues. The flows of the other two furnaces are the same as that of the furnace (F101/3), but the corresponding coke towers are different. The coke towers (T101/1, 2) are for the furnace (F101/1) and (T101/3, 4) for the furnace (F101/2). Each time, only one of each pair of coke towers works for its corresponding furnace, and when it is full, the other one replaces it. This replacement is called the switch of coke towers and the procedure recycles. The switch time of three pairs of coke towers is different. The heat exchange with gas oil from the coke towers poses a continuous disturbance on the outlet temperature because of the volume of the gas oil from the coke towers. During the switch of the coke towers, the outlet temperature of the furnace often drops and rises sharply because some of the oil in it will become gas oil, and part of the inlet gas oil flowing into it will be used for the heating of coke towers. What’s more, the random switch time of three pairs of coke towers adds to this serious problem.
Fig. 6.1Overall flow of coke unit
Download
This site does not store any files on its server. We only index and link to content provided by other sites. Please contact the content providers to delete copyright contents if any and email us, we'll remove relevant links or contents immediately.
Algorithms of the Intelligent Web by Haralambos Marmanis;Dmitry Babenko(8309)
Test-Driven Development with Java by Alan Mellor(6776)
Data Augmentation with Python by Duc Haba(6691)
Principles of Data Fabric by Sonia Mezzetta(6437)
Learn Blender Simulations the Right Way by Stephen Pearson(6337)
Microservices with Spring Boot 3 and Spring Cloud by Magnus Larsson(6211)
Hadoop in Practice by Alex Holmes(5965)
Jquery UI in Action : Master the concepts Of Jquery UI: A Step By Step Approach by ANMOL GOYAL(5813)
RPA Solution Architect's Handbook by Sachin Sahgal(5608)
Big Data Analysis with Python by Ivan Marin(5388)
The Infinite Retina by Robert Scoble Irena Cronin(5300)
Life 3.0: Being Human in the Age of Artificial Intelligence by Tegmark Max(5155)
Pretrain Vision and Large Language Models in Python by Emily Webber(4353)
Infrastructure as Code for Beginners by Russ McKendrick(4117)
Functional Programming in JavaScript by Mantyla Dan(4042)
The Age of Surveillance Capitalism by Shoshana Zuboff(3961)
WordPress Plugin Development Cookbook by Yannick Lefebvre(3833)
Embracing Microservices Design by Ovais Mehboob Ahmed Khan Nabil Siddiqui and Timothy Oleson(3633)
Applied Machine Learning for Healthcare and Life Sciences Using AWS by Ujjwal Ratan(3606)
